欢迎访问过程工程学报, 今天是

›› 2008, Vol. 8 ›› Issue (5): 839-844.

• 流动与传递 • 上一篇    下一篇

气固流化床固体浓度分布的冷模研究

蔡进 李涛 孙启文 应卫勇 房鼎业   

  • 收稿日期:2008-05-15 修回日期:2008-07-02 出版日期:2008-10-20 发布日期:2008-10-20

Solid Concentration Distribution in a Gas-Solid Fluidized Bed

CAI Jin LI Tao SUN Qin-wen YING Wei-yong FANG Ding-ye   

  • Received:2008-05-15 Revised:2008-07-02 Online:2008-10-20 Published:2008-10-20

摘要: 在内径0.284 m、高6.0 m的气固流化床冷模装置中进行了气固流化实验,采用PC6 D型颗粒浓度测试仪检测固体浓度. 分别采用枝条型(开孔率a=5‰和2.5‰)和环形(a=5‰)气体分布器,以直径154~180 mm、密度2550 kg/m3的砂子为颗粒,在静床高H0=0.6~1.5 m、表观气速u=0.3~0.6 m/s的情况下,考察了时均固体浓度1-e在空间的分布. 结果表明,增加u使密相区的1-e减小,分布器形状对1-e影响不大. 采用较低a的分布器时1-e的变化较大,且其值均较低. H0=0.6 m, 轴向位置H=0.4 m, u=0.3 m/s, 径向位置r=0~0.142 m时,1-e由0.410上升到0.494;H0=0.6 m, H=0.4~0.95 m, u=0.3 m/s, r=0时,1-e从0.410减小到0;H0=1.5 m, H=0.4~1.3 m, u=0.3 m/s, r=0时,1-e从0.397先下降到0.372,再上升到0.424,最后下降到0.328.

关键词: 固体浓度, 气固流化床, 分布器, 静床高, 开孔率

Abstract: The experiments were conducted in a cold conventional fluidized bed using fiber optical probe as the detecting apparatus. The system compromises a replaceable gas distributor in a 0.284 m internal diameter acrylic column, a compressor, a series of knock-out drum, a freezer dryer, a rotameter, a fiber optic probe system and a series of cyclone. The experiments were carried out at ambient conditions and under different superficial gas velocities ranging from 0.3 to 0.5 m/s and different initial bed height ranging from 0.6 to 1.5 m using air as the fluidizing gas. A mixture of sands ranging from 154 to 180 mm diameter and average density of 2550 kg/m3 were used as the fluidizing particles. The effects of radial distance, axial distance, superficial gas velocity, initial bed height, porosity and shape of distributor on solid concentration in the bed were examined. The experimental results show that the time-averaged solid concentration increases in the dense phase area with the increase of superficial gas velocity. The shape of distributor does not exert much influence on the solid concentration while the smaller porosity of distributor gives rise to a lower and steeper solid concentration distribution. The initial bed height influences the solid concentration distribution contours significantly.

Key words: solid concentration, gas-solid fluidized bed, distributor, initial bed height, porosity

中图分类号: