欢迎访问过程工程学报, 今天是

›› 2011, Vol. 11 ›› Issue (1): 9-14.

• 流动与传递 • 上一篇    下一篇

多级气液鼓泡塔中筛板结构对气垫层高度及局部气含率的影响

秦岭 靳海波 杨索和 何广湘 朱建华   

  1. 北京石油化工学院化工系 北京石油化工学院化工系 北京石油化工学院化工系 北京石油化工学院化工系 中国石油大学(北京)化工学院
  • 收稿日期:2010-07-05 修回日期:2011-02-11 出版日期:2011-02-20 发布日期:2011-02-20
  • 通讯作者: 靳海波

Effect of Sieve Plate Structure on Gas Cap Height and Local Gas Holdup in a Multistage Bubble Column Reactor

QIN Ling JIN Hai-bo, YANG Suo-he HE Guang-xiang ZHU Jian-hua   

  1. Department of Chemical Engineering, Beijing Institute of Petrochemical Technology Department of Chemical Engineering , Beijing Institute of Petrochemical Technology Department of Chemical Engineering, Beijing Institute of Petrochemical Technology Dept. Chem. Eng., Beijing Inst. Petrochem. Technol. Faculty of Chemical Science and Engineering, China University of Petroleum
  • Received:2010-07-05 Revised:2011-02-11 Online:2011-02-20 Published:2011-02-20
  • Contact: JIN Hai-bo,

摘要: 采用压差法和双电导探针法考察了筛板结构对f300 mm多级鼓泡塔中筛板下侧气垫层高度和筛板上下两处局部气含率的影响. 结果表明,气垫层高度随表观气速ug增加而增加,随开孔率降低而增加,当ug从0.04 m/s增加到0.24 m/s时,气垫层高度从0.01 m增加到0.06 m. 而局部气含率的径向分布与普通鼓泡塔相似,都随ug增加而增加,随径向位置r/R增加而减小;筛板的引入使局部气含率在轴向方向发生较大变化,ug=0.027 m/s时,筛板上下两侧的局部气含率均在0.05左右,但ug增加到0.11 m/s时,下侧气含率则普遍增加到0.3~0.35,而上侧则在0.25~0.3之间,下侧普遍比上侧气含率高.

关键词: 多级鼓泡塔, 气垫层高度, 压差法, 双头电导探针法, 局部气含率

Abstract: The effect of sieve plate structure on the gas cap height and local gas holdup in a f300 mm multistage bubble column was studied using differential-pressure method and double-sensor conductivity probe. The experimental results show that the gas cap height increases with the increase of superficial gas velocity, ug, and decrease of opening area of the sieve plates. The gas cap height increases from 0.01 to 0.06 m while ug increases from 0.04 to 0.24 m/s. Moreover, the radial distribution of gas holdup in the reactor is similar to that in a regular bubble column. The average gas holdups above and under the plate increase with the increase of ug. For the axial distribution of gas holdups, when ug is about 0.027 m/s, the gas holdups above and under the plate are all around 0.05. But when ug becomes 0.11 m/s, the gas holdup under the plate is about 0.3~0.35, which is much higher than the one above plate with around 0.25~0.3.

Key words: multistage bubble column, gas cap height, differential-pressure method, double-sensor conductivity probe, local gas holdup

中图分类号: